อุปกรณ์วัด Turbidity (benchtop instrument for measuring turbidity according to ISO 7027)

HI 88713-02 benchtop instrument for measuring turbidity  according to ISO 7027

HI 88713-02 benchtop instrument for measuring turbidity  according to ISO 7027

HI 88713 is a professional tool for high accuracy, which benefits from HANNA’s years of experience in the production of analytical instruments.
HI 88713 is designed to meet and exceed the requirements of ISO 7027.
The special optical system ensures accurate results, assures a long-term stability and minimizes interference due to color and scattered light. It is also able to compensate for variations in intensity of the light source, eliminating the need for frequent calibration.
cuvettes are constructed with a special optical glass guarantee the repeatability of measurements.
Turbidity measurements can be performed in four scales: 0.00 to 1000 FNU (Formazin Nephelometric Units) mode FNU, 10 to 4000 FAU (Formazin Attenuation Units) mode FAU, 0.00 to 4000 NTU (Nephelometric Turbidity Units) in NTU ratiometric mode and from 0.00 to 1000 NTU NTU mode does not ratiometric. From the two modes NTU is also possible to display readings in EBC units.
Depending on the measured sample and needed accuracy, you can select the normal measurement mode, continuous or signal averaging. The calibration can be performed on two, three, four or five points using the standard supplied (<0.1, 15, 100, 750 FNU and 2000 NTU). If you use standard prepared by the user, you can edit the calibration points.
HI 88713 is equipped with GLP (Good Laboratory Practice) that allow the calibration traceable test conditions: in fact you can check the calibration points used, the ‘Time and date of last calibration user. HI 88713 is equipped with user-friendly interface with large graphic display. All messages are displayed in an extensive way, without using codes difficult to understand. In addition, a context-sensitive online help is always available at the touch of a button. Finally, an instructive mode provides additional information and explanations to accompany the operator at all stages of the analysis. The instrument displays the messages, online help and instructions in Italian.
recording function data enjoys a memory that can store up to 200 measurements, complete with date, time, and parameter measurement units. These data can be recalled at any time or downloaded to a PC through the USB port and the software HANNA HI 92000.

 Specifications

Stray Light    <0.1 NTU (0:05 EBC)
Sensor / i    silicon photocell
Measurement mode    Normal, continuous, signal averaging
Standard    <0.1, 15, 100, 750, and 2000 NTU
Calibration    steps 2, 3, 4 or 5 points
Light Source    IR LEDs at 890 nm
Duration source    life of the instrument
Display    graphic display, 64 x 28 pixels, with backlight
Storing    200 samples
Interfaces    USB port
Terms of use    up to 50 ° C max 95% RH non-condensing
Supply    input 12 Vdc adapter
Dimensions and weight    230 x 200 x 145 mm / 2.5 kg

Quotation and Ordering
131 Thailand Science Park. Innovation Cluster 1 Building, Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. +6681-847-6768, +662-191-3928 Fax +662-191-3929 Mr.Thoniwadh +6685-811-4779, Ms.Nareerat +6685-814-9653
Email: info@highents.com

สนใจขอใบเสนอราคาและสั่งซื้อสินค้า
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 ต. คลองหนึ่ง อ. คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟกซ์ 02-191-3929 คุณโทณิวัฒน์ 085-811-4779, คุณนารีรัตน์ 085-814-9653
Email : info@highents.com

 

  •  

    >>> ขอใบเสนอราคาแบบออนไลน์ คลิก !!

  • Scroll To Top

    Contact Us