อุปกรณ์วัด Photometer for the Determination of Copper in Wine

HI83740 Photometer for the Determination of Copper in Wine

HI 83740

Photometer for the Determination of Copper in Wine

Grapes normally accumulate only a small amount of copper by natural translocation from roots. Unless exposed to significant airborne pollution or vineyard sprays, increased concentrations in wine result from contamination during post fermentation processing, like contact with non stainless steel  equipment and as impurities in fining agents and filter media.

The copper concentration in wine is normally low, less that 0.10 to 0.30 mg/L (ppm), because excess copper is precipitated during fermentation due to adsorption onto the yeast cells. This adsorption and precipitation can reduce the initial copper concentration with 40 to 89%. At higher concentration copper plays an important role in catalyzing oxidation reactions of wine phenols.

It is important to check the copper content both in must and in wine, because at levels about 9 mg/L (ppm) copper becomes a metabolic toxin that inhibits or delays alcoholic fermentation, and concentrations exceeding 1 mg/L (ppm) may be sensorially detected and should be avoided.

Other copper related problems can be manifested as formation of white haze (in white wines) and later as a reddish brown amorphous precipitate. This precipitated “casse” develops only under the strongly reducing conditions found in bottled wines. It has been found that this casse is a mixture of copper compounds and proteins.

HANNA’s HI 83740 is an invaluable instrument to monitor this crucial parameter in the winemaking process.

Order Information:
HI 83740-01 (115V) and HI 83740-02 (230V) are supplied with sample cuvettes and caps (2), reagents for 5 tests (HI 83740A-O, HI 83740B-O, HI 83740C-O, HI 83740D-O), 20 mL glass vials with caps (2), 1 mL plastic pipette (2), 3 mL plastic pipette (2), spoons (2), cuvette cleaning cloth, 12 VDC adapter, batteries, instructions, instrument quality certificate and rugged carrying case.

Specifications

Range 0.00 to 1.50 mg/L
Resolution 0.05 mg/L
Accuracy @25°C ±0.05 mg/L ±5% of reading
Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 560 nm
Method extraction method 2.2 bichinoline
Environment 0 to 50°C; RH max 95% non-condensing
Power Supply 1.5V AA batteries (4) / 12 VDC adapter
Auto-off after 15 minutes of non-use
Dimensions 225 x 85 x 80 mm (8.7 x 3.3 x 3.1”)
Weight 500 g (17.6 oz.)

สนใจขอใบเสนอราคาและสั่งซื้อสินค้า
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 ต. คลองหนึ่ง อ. คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟกซ์ 02-191-3929 คุณโทณิวัฒน์ 085-811-4779, คุณนารีรัตน์ 085-814-9653
Email : info@highents.com

Quotation and Ordering
131 Thailand Science Park. Innovation Cluster 1 Building, Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. +6681-847-6768, +662-191-3928 Fax +662-191-3929 Mr.Thoniwadh +6685-811-4779, Ms.Nareerat +6685-814-9653
Email: info@highents.com

 

  •  

    >>> ขอใบเสนอราคาแบบออนไลน์ คลิก !!

  • Scroll To Top

    Contact Us