อุปกรณ์วัด Cyanide Portable Photometer

HI96714 Cyanide Portable Photometer

HI 96714

Cyanide Portable Photometer

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

The HI 96714 meter measures the cyanide concentration in waters.  The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.

Cyanide is a pollutant that originates mostly from metalurgicaland galvanic industrial plants. Cyanide is poisonous to human nervous system, and it is therefore imperative to monitor and control its level in potable water. Continuous monitoring in waste effluents is required, and cyanide is removed using alkaline chlorination procedure. Due to this, European norm limit the concentration of cyanide in drinking water to 0.05 mg/L, while the EPA has established that the maximum level is not to exceed 0.2 mg/L.

Order Information:
HI 96714 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.

Specifications

Range 0.000 to 0.200 mg/L
Resolution 0.001 mg/L
Accuracy ±0.005 mg/L ±3% of reading @ 25°C
Light Source Tungsten Lamp
Light Detection silicon photocell with narrow band interference filter @ 610 nm
Battery Type / Life 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight 360 g (12.7 oz.)
Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Pyridine-Pyrazolone method

สนใจขอใบเสนอราคาและสั่งซื้อสินค้า
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 ต. คลองหนึ่ง อ. คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟกซ์ 02-191-3929 คุณโทณิวัฒน์ 085-811-4779, คุณนารีรัตน์ 085-814-9653
Email : info@highents.com

Quotation and Ordering
131 Thailand Science Park. Innovation Cluster 1 Building, Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. +6681-847-6768, +662-191-3928 Fax +662-191-3929 Mr.Thoniwadh +6685-811-4779, Ms.Nareerat +6685-814-9653
Email: info@highents.com

 

  •  

    >>> ขอใบเสนอราคาแบบออนไลน์ คลิก !!

  • Scroll To Top

    Contact Us